ISO 9001 Certified·Domestic Manufacturer — Houston, TX
Hot-shot line open832-446-3442
Innovation FastenersInnovation Fasteners
HomeEmergency / Hot-shot 24/7ContactGet a Quote
Testing · Will it stay tough in the cold?

Charpy V-notch impact testing

Step by step in 3D
Press play, or step through with the arrows under the picture. Full screen from the top corner.

Steels used for bolting get less tough as they get colder, and below a certain temperature they can snap with little warning. The Charpy test breaks a notched bar with a swinging pendulum and measures how much energy it absorbs at the test temperature.

αPIVOTPENDULUM, RAISEDSTRIKERSWINGSPECIMENANVILDETAIL · SPECIMEN ON SUPPORTS55 MM40 MM SPAN10V-NOTCH 2 MM · 45° · R 0.25 MMTESTCHARPY V-NOTCH IMPACTMETHODASTM E23 · A370
The bar rests on supports 40 mm apart with its notch facing away from the striker. The energy it absorbs is the height the pendulum loses.
How it works

Five steps, one swing.

  1. STEP 01

    Machine three specimens

    Bars 10 × 10 × 55 mm are cut lengthwise from the material, from the centre of sizes up to 1 in. and halfway between centre and surface on larger ones, with a 2 mm, 45° V-notch across the middle.

  2. STEP 02

    Chill to temperature

    They soak in a bath held within ±2 °F of the test temperature, for at least 5 minutes in a liquid or 30 in a gas.

  3. STEP 03

    Onto the supports

    Tongs shaped to fit the notch set each bar on the supports, notch facing away from the striker. If the pendulum is not released within 5 seconds, the bar goes back in the bath.

  4. STEP 04

    Release the pendulum

    Let go from a fixed height, the pendulum strikes the face opposite the notch at 16 to 19 ft/s (4.9 to 5.8 m/s) and breaks the bar.

  5. STEP 05

    Read the energy

    The machine gives the energy absorbed in ft·lbf or joules. Lateral expansion and percent shear can be measured on the broken halves.

What it can't do
  • A result holds only at its test temperature: a bar that passes at −50 °F may fail at −150 °F.
  • Bolting 1/2 in. and smaller is exempt from impact testing under ASTM A320.
  • Material too small for a full-size bar is tested with standard subsize specimens, such as 10 × 7.5 mm, which absorb less energy, so the required figures are lower to match.
Why it matters for fasteners

Below its transition, steel breaks like glass.

Ferritic steels such as the 4140 in a B7 stud change from ductile to brittle over a range of temperature. Above it they tear and absorb a lot of energy; below it they break by cleavage, absorbing far less.

Bolting for low-temperature service is made to ASTM A320, whose ferritic grades are impact tested at a set temperature: L7 and L43 at −150 °F, L7M at −100 °F, each needing an average of 20 ft·lbf from three full-size specimens with none below 15 ft·lbf. L1 is tested at −100 °F to a 40 ft·lbf average.

The nuts are covered too. With A320 ferritic bolting, the nut material is impact tested and the nuts are marked with an L, such as 7L for A194 Grade 7.

Where it applies

Grades and specifications.

ASTM A320 L7−150 °F: 20 ft·lbf average, 15 ft·lbf single, full size.
ASTM A320 L43As L7, at −150 °F; the grade for larger diameters, to 4 in.
ASTM A320 L7M−100 °F: 20 ft·lbf average, 15 ft·lbf single; hardness capped at 235 HBW.
ASTM A320 L1−100 °F: 40 ft·lbf average, 30 ft·lbf single.
ASTM A194 Grade 7 nutsImpact tested when supplied with A320 bolting and marked 7L; on their own, by supplementary requirement S3 (not required below 5/8 in.).
ASTM A193 B7No impact requirement; testing can be added as supplementary requirement S2.
MethodASTM A370 and E23 · acceptance per ASTM A320 Table 2 (20 ft·lbf average for L7 at −150 °F; 40 ft·lbf for L1 at −100 °F) or the purchaser's specified temperature
On the certificate

What the report shows.

  • The test temperature.
  • The three energy values and their average.
  • Lateral expansion and percent shear, when they are asked for.
  • Specimen size, if subsize specimens were used.
Ordering

How to ask for it.

  • Name the grade, for example A320 L7; its impact requirement and test temperature come with it.
  • If your design needs a test temperature colder than the grade's, give it on the order; the bolting is marked to suit.
  • Ask for lateral expansion if your code needs it (A320 supplementary requirement S2 sets 0.015 in. minimum).
Ask for this test with a quote
Questions

Charpy V-notch impact testing: common questions.

Does a B7 stud need Charpy testing?

No. ASTM A193 has no impact requirement for B7; it can be added as supplementary requirement S2. For low-temperature service, order A320 L7, which is impact tested at −150 °F.

What is the difference between B7 and L7?

Both are quenched-and-tempered chromium-molybdenum steel with the same strength, 125 ksi tensile and 105 ksi yield up to 2-1/2 in. L7 must also pass Charpy impact tests at −150 °F; B7 does not.

Why three specimens?

Charpy results scatter, so when the specification sets a minimum average, three specimens make one test (ASTM A370). A320 also sets a minimum for each single specimen.

What does “room temperature” mean for Charpy?

Lab temperature can be anywhere from 60 to 90 °F, so a room-temperature test could be run anywhere in that range (ASTM A370). If it matters, give a temperature.

Need this test on your next order?

Send the specification and the test you need, and we will quote it with the parts · 832-446-3442
Get a Quote