ISO 9001 Certified·Domestic Manufacturer — Houston, TX
Hot-shot line open832-446-3442
Innovation FastenersInnovation Fasteners
HomeEmergency / Hot-shot 24/7ContactGet a Quote
Quality · Testing & inspection

Every claim on the certificate, checked on the bench.

A material test report tells you what the mill poured. These tests tell you what we shipped. Each one is run to the ASTM method the specification calls for, on your lot, and reported on the certificate that travels with the parts.

23 methods · Mechanical

Strength, toughness and hardness.

Tensile testing3D animation
Does it meet the strength table?

Tensile testing

The full-size fastener is pulled to failure to prove the load it carries, and a specimen machined from the lot gives tensile strength, 0.2 percent offset yield, elongation and reduction of area. All are compared with the grade's table by diameter.

Method
ASTM A370 and F606 · acceptance per ASTM A193 Table 2, A320 Table 1, A453, or the alloy specification
When
Per heat-treat lot on alloy and stainless bolting; full-size testing after strain hardening is used for Class 2 austenitic bolting.
Watch how the test works in 3D
Wedge tension testing of bolts3D animation
Is the head as sound as the shank?

Wedge tension testing of bolts

The finished bolt is pulled to failure with a hardened wedge under its head, so the head bends as the load rises. It must reach its minimum tensile load and break in the threads or shank; a break where the head meets the shank fails the test at any load.

Method
ASTM F606/F606M and A370 Annex A3 · ISO 898-1 for metric bolts and screws · requirements per the product specification, for example ASTM A193, A320, A449, A354, F3125 and A574
When
When the product specification calls for it: on upset or forged headed A193 and A320 bolts 1-1/2 in. and under, three diameters long or more, and on hex bolts to A449, A354 and F3125 long enough for the test (2-1/4 diameters up to 1 in., three diameters above).
Watch how the test works in 3D
Proof load testing of nuts3D animation
Will the nut carry the bolt's full load?

Proof load testing of nuts

The nut is threaded on a hardened mandrel and loaded to the proof stress for its grade and size. It passes if the threads neither strip nor break and it can be removed by hand afterwards; a wrench may start it, for up to half a turn.

Method
ASTM A194 Table 3 and F606 · proof stress by grade and style, for example 175 ksi for 2H heavy hex nuts (150 ksi hex) and 80 ksi for Grade 8
When
Per lot on A194 nuts, and on every lot of L-marked nuts supplied with low-temperature bolting.
Watch how the test works in 3D
Cone proof load testing of nuts3D animation
Does a visible mark weaken the nut?

Cone proof load testing of nuts

The nut is threaded onto a hardened mandrel and loaded through a hardened 120° cone, which spreads it open while its threads carry the load. It must hold the cone proof load without stripping or rupture, which shows whether a forging crack or seam reduces its strength.

Method
ASTM F606/F606M and A962/A962M · cone proof stresses per ASTM A194 Tables 5 and 6 · nut surface discontinuities per ASTM F812/F812M
When
Only when visible surface discontinuities on hardened steel nuts are in question: ASTM A194 nuts 1/4 to 1-1/2 in. (M12 to M36), any grade except Grade 8.
Watch how the test works in 3D
Hardness testing3D animation
Is the heat treatment right, and is it soft enough for sour service?

Hardness testing

A Rockwell or Brinell indenter is pressed into the part and the indentation measured. Hardness tracks the heat treatment, so it catches an under-tempered lot, and sour-service grades carry a hardness ceiling that every piece must meet.

Method
ASTM E18 (Rockwell) and E10 (Brinell) · limits per ASTM A193, A194 and A320 by grade
When
Every lot of heat-treated bolting; piece by piece on B7M, L7M, 2HM and 7M, where the specifications require 100 percent hardness testing.
Watch how the test works in 3D
Charpy V-notch impact testing3D animation
Will it stay tough in the cold?

Charpy V-notch impact testing

A notched specimen machined from the lot is chilled to the test temperature and struck by a swinging hammer; the energy it absorbs before breaking is the result. Low-temperature grades must absorb a minimum energy at temperature, which is the difference between a B7 and an L7.

Method
ASTM A370 and E23 · acceptance per ASTM A320 Table 2 (20 ft·lbf average for L7 at −150 °F; 40 ft·lbf for L1 at −100 °F) or the purchaser's specified temperature
When
Every lot of A320 L7, L7M, L43 and the other ferritic low-temperature grades, and the nuts supplied with them; austenitic grades, and A194 nuts ordered on their own, when the service temperature requires it.
Watch how the test works in 3D
Elevated-temperature tensile testing3D animation
How strong is it at service temperature?

Elevated-temperature tensile testing

A machined specimen is heated in a furnace, held at the test temperature and pulled to failure, giving tensile strength, yield strength, elongation and reduction of area at temperature. It is a short test: it shows strength when hot, not how long a bolt will last there.

Method
ASTM E21 · minimums per the material specification or the order, for example ASTM A1014 for alloy 718 bolting at 1200 °F, ASTM F2281 supplementary requirement S8, ASTM A193 supplementary requirement S1
When
When the material specification sets hot tensile minimums, as ASTM A1014 does for alloy 718 bolting, or when the order calls for it under ASTM A193 S1 or F2281 S8.
Watch how the test works in 3D
Stress-rupture testing3D animation
Will it carry its load at temperature for the hours required?

Stress-rupture testing

A specimen is held at a set temperature under a constant load until it breaks; the hours to rupture and the elongation must reach the specified minimums. Bolting specifications use a combination bar with a smooth section and a V-notch of the same diameter: it must break in the smooth section, showing the material is not notch sensitive.

Method
ASTM E139 and E292 · requirements per ASTM A453 Table 6, B637 Table 4, A1014, and A193 supplementary requirement S12 for B16
When
On ASTM A453 Grades 660 (Classes A, B and C), 651, 662 and 665 for design temperatures above 800 °F, with each tension test; per lot on alloy 718 to A1014 or B637 and the other alloys in B637 Table 4; on B16 when S12 is ordered.
Watch how the test works in 3D
Inspection and NDT

Flaws, cracks and dimensions, without cutting the part.

Magnetic particle inspection (MPI)3D animation
Any cracks or laps in the surface?

Magnetic particle inspection (MPI)

The part is magnetised and dusted with fine iron particles, dry or in a fluorescent suspension. A crack, seam or lap at or just under the surface breaks the magnetic field and the particles gather along it, showing a defect the eye cannot see.

Method
ASTM E709 and E1444 · acceptance per the purchase order or drawing
When
On request for alloy-steel studs and forgings, and as standard on rotating-equipment and OEM turbine bolting.
Watch how the test works in 3D
Liquid penetrant inspection (LPI)3D animation
Surface defects on stainless and nickel alloys

Liquid penetrant inspection (LPI)

A low-viscosity dye is drawn into any surface-breaking defect, the excess is cleaned off, and a developer pulls the trapped dye back out as a visible line. It does the job of magnetic particle inspection on materials that cannot be magnetised.

Method
ASTM E165 and E1417
When
Austenitic stainless, duplex, nickel-alloy and non-ferrous parts where a surface inspection is specified.
Watch how the test works in 3D
Ultrasonic testing (UT)3D animation
Is the bar sound all the way through?

Ultrasonic testing (UT)

A transducer sends sound pulses into the part and listens for reflections. An internal void, inclusion or lamination returns an echo before the back wall does, so the whole cross-section of a large stud or bar is checked without cutting it.

Method
ASTM A388 and E114
When
Large-diameter studs, turbine and heat-exchanger bolting, and bar over 2 in. when the purchaser specifies it.
Watch how the test works in 3D
Surface discontinuity inspection3D animation
Are the marks on the part within the limits?

Surface discontinuity inspection

Bolts, studs and nuts are examined for cracks, bursts, seams, folds, laps, voids, tool marks, nicks and gouges, and each is judged against the limit for its type and location. Magnetic particle or penetrant inspection shows an indication's full extent; examining a sample under a microscope, or grinding it down, shows its depth.

Method
ASTM F788/F788M (bolts, screws, studs) and F812/F812M (nuts), both active · ISO 6157-1, -2 and -3 · workmanship clauses of ASTM A962, A193, A194, A320, A574 and the other product specifications
When
Whenever the product specification invokes ASTM F788 or F812, as A193, A194 and A320 do through A962 and A449, A354, A307 and F3125 do directly; closer limits, or magnetic particle inspection, when the specification or the order calls for them.
Watch how the test works in 3D
Thread gauging and dimensional inspection3D animation
Does every dimension and thread meet the drawing?

Thread gauging and dimensional inspection

Threads are checked with Go and No-Go ring and plug gauges, and pitch diameter is measured by the three-wire method or on a thread comparator. Heads, flats, lengths and radii are measured with calibrated instruments and, for complex parts, on the CMM.

Method
ASME B1.1 threads · ASME B1.2 and B1.3 gauging practice · ASME B18.2.1, B18.2.2, B18.3 and B18.31.2 dimensions
When
Every job, first-off and in process; a full dimensional report is available on request.
Watch how the test works in 3D
Chemistry and metallurgy

What the steel is, and what the mill and heat treatment did to it.

Positive Material Identification (PMI)3D animation
Is the alloy what the paperwork says?

Positive Material Identification (PMI)

A handheld X-ray fluorescence analyser reads the chemistry of the finished part in seconds and matches it to the grade. It confirms that a B7 is chromium-molybdenum steel and not plain carbon, that a B8M has its molybdenum, and that a nickel-alloy stud is the alloy on the certificate. Handheld XRF does not read carbon, so carbon is confirmed from the mill certificate or by spark (OES) analysis.

Method
ASTM E1476 · results reported against the grade's chemistry in ASTM A193, A194, A320 or the alloy specification
When
Standard practice on nickel alloys, duplex and every mixed-material order; available on any lot at no charge when requested with the order.
Watch how the test works in 3D
Chemical analysis (heat and product)3D animation
Is the chemistry right, carbon and all?

Chemical analysis (heat and product)

The steel mill analyses every heat and reports it on the certificate. A product (check) analysis samples the finished part and measures it by spark emission and combustion, or by ICP or X-ray fluorescence for nickel alloys. The result is held to the grade's limits plus the small product-analysis tolerance the specification allows. Unlike handheld PMI, it reads carbon, boron and nitrogen.

Method
ASTM A751 · E415 and E1086 (spark emission) · E1019 (carbon, sulfur, nitrogen) · E1473, E2594 and E2465 (nickel alloys) · tolerances per ASTM A193, A320, A484 and B880
When
Heat analysis comes with every heat on the mill certificate; product analysis when the specification or the order calls for it.
Watch how the test works in 3D
Ferrite content and phase balance3D animation
Is the duplex balanced, and free of sigma?

Ferrite content and phase balance

A polished section of duplex stainless is point-counted to measure how much of it is ferrite. ASTM A923 shows whether harmful intermetallic phases such as sigma are present, by an etch screen, a Charpy test or a ferric chloride corrosion test. For austenitic parts that must be non-magnetic, relative magnetic permeability is measured instead.

Method
ASTM E562 (point count) · ASTM A923 Methods A, B and C (A1084 for lean duplex) · ASTM A342 (permeability) · AWS A4.2 and ISO 8249 (Ferrite Number, weld metal)
When
When the purchaser's specification or the order sets a ferrite range, an A923 test or a permeability limit. The bar and bolting specifications do not require them by default.
Watch how the test works in 3D
Decarburization and carburization3D animation
Has heat treatment changed the thread surface?

Decarburization and carburization

A finished part is cut lengthwise through the thread, etched and micro-hardness tested. This measures any carbon lost from the thread surface (decarburization) or gained (carburization). The limits tighten with strength: Class 3, for the hardest bolts and screws, allows no gross decarburization at all.

Method
ASTM F2328 (inch) and F2328M (metric) · ISO 898-1 (property classes 8.8 to 12.9) · limits per ASTM A962, A574, F835, F912, A354 and F3125
When
When the product specification calls for it, as A962 does for carbon and alloy steel bolting and A574 for socket head cap screws, or when the order asks.
Watch how the test works in 3D
Macroetch3D animation
Is the steel sound inside, and how does the grain flow?

Macroetch

A slice cut from the bar or from a sample forging is etched in hot acid and examined by eye or at low magnification. It shows pipe, porosity, cracks, seams and segregation, and the flow lines left by forging. It is rated against graded standard photographs.

Method
ASTM E381 (steel bars, billets, blooms and forgings) · ASTM E340 (macroetching, forging flow lines) · A962 limit S2-R2-C3 for ingot-cast bolting steel
When
Once per heat and size on carbon and alloy bolting steel (ASTM A962, reported on A193 and A194 certificates); on sample forgings when the order calls for it.
Watch how the test works in 3D
Metallography: inclusions and grain size3D animation
How clean is the steel, and how fine is its grain?

Metallography: inclusions and grain size

A polished section is examined under the microscope. Non-metallic inclusions are rated by type (sulfide, alumina, silicate and globular oxide) and by thickness. The grain size is measured as an ASTM grain size number, where a higher number means finer grains.

Method
ASTM E45 (inclusion content) · ASTM E112 (average grain size) · ASTM E3 (specimen preparation)
When
When the specification or the order sets a limit. Examples: grain size No. 7 or coarser on austenitic bolting for service above 1000 °F (A193 S9, A194 S6), or fine-grain steel for alloy socket screws (A574).
Watch how the test works in 3D
Corrosion and coatings

Finishes, hydrogen and corrosion resistance.

Coating thickness and salt spray3D animation
Is the plating thick enough, and will it last?

Coating thickness and salt spray

Coating thickness is measured with a magnetic or eddy-current gauge, or by X-ray fluorescence for thin platings, and checked against the class ordered. Salt-spray exposure checks corrosion protection on a sample from the lot when the specification calls for it.

Method
ASTM B499, B568 and E376 (thickness) · ASTM B117 (salt spray) · ASTM F1941 and B633 (zinc classes)
When
Every plated or coated lot has its thickness checked; salt spray on request or where the coating specification requires it.
Watch how the test works in 3D
Hydrogen embrittlement relief and testing3D animation
Will a plated high-strength bolt crack in service?

Hydrogen embrittlement relief and testing

High-strength steel can pick up hydrogen during pickling and plating and fail days later under load. Parts above 39 HRC are baked after plating to drive the hydrogen out, and a sustained-load test on fasteners from the lot proves the relief worked.

Method
ASTM F1941 (baking above 39 HRC) · ASTM F606 (sustained-load test on the lot) · ASTM F1940 and F519 (plating process control)
When
Every plated lot of parts above 39 HRC.
Watch how the test works in 3D
Intergranular corrosion testing3D animation
Has the stainless been sensitized?

Intergranular corrosion testing

Austenitic stainless that has formed chromium carbides along its grain boundaries can corrode along them. ASTM A262 screens with an oxalic acid etch (Practice A) and tests with acid exposures. Stainless bar and fastener specifications name Practice E: a copper–copper sulfate–sulfuric acid exposure followed by a bend test. Nickel alloys such as 625 and C-276 are tested to ASTM G28.

Method
ASTM A262 Practices A, B, C, E and F · ASTM G28 Methods A and B (nickel alloys) · ASTM A923 (duplex)
When
When the order or the purchaser's specification calls for it; A193, A194, A320 and A962 do not include it.
Watch how the test works in 3D
Pitting corrosion testing3D animation
Will it pit in chloride service?

Pitting corrosion testing

Samples are exposed to ferric chloride solution to rank their resistance to pitting and crevice corrosion, or tested at a series of temperatures to find the critical pitting temperature. It is used on duplex, super duplex, 6% molybdenum austenitic grades and nickel alloys, and it shows whether the material lives up to its PREN.

Method
ASTM G48 Methods A to F · ASTM A923 Method C (duplex acceptance) · PREN = Cr + 3.3(Mo + 0.5W) + 16N
When
When the purchaser's material specification calls for it. G48 sets no acceptance criteria of its own, so the order must give them.
Watch how the test works in 3D
How testing is ordered

Say what you need on the purchase order.

The specification sets the minimum: tensile and hardness per lot, Charpy on low-temperature grades, proof load on nuts. Anything beyond that is ordered as a supplementary requirement, and the cost is usually small compared with a rejected shipment.

  • Reference the supplementary requirement. ASTM A193, A194 and A320 list them by number, and ASTM A962 adds common ones such as PMI and 100% magnetic particle testing; "A193 B7, supplementary requirement S7 (magnetic particle)" is all we need.
  • Give the test temperature. Charpy results only mean something at the temperature your design needs; −50 °F and −150 °F are different tests.
  • Ask for the certificate level. EN 10204 3.1 is standard; 3.2 adds an independent witness and needs scheduling.
  • Name the NDE acceptance. Magnetic particle, penetrant and ultrasonic results are judged against a criterion, so send the drawing note or standard.
  • Tell us the service. Sour, cryogenic, hydrogen or seawater duty changes which tests we run before you ask.

Need a witnessed test, or a report on a lot you already have?

Send the specification and we will quote the testing with the parts · 832-446-3442