Testing · Is the heat treatment right, and is it soft enough for sour service?

Hardness testing

Step by step in 3D
Press play, or step through with the arrows under the picture. Full screen from the top corner.

Hardness is the fastest check on a heat treatment. A hard indenter is pressed into the part, and the size or depth of the dent gives the number. It also enforces the upper limits that sour-service bolting depends on.

1 · PRELOAD2 · TOTAL FORCE3 · BACK TO PRELOADhROCKWELL: THE READING COMES FROM THE PERMANENT DEPTH hPRELOAD 10 KGF · HRC: DIAMOND CONE, 150 KGF · HRB: 1/16 IN. BALL, 100 KGFBRINELL10 MM BALL · 3000 KGFdPART UNDER TESTWhere and how many readings:as the product specification setsTESTROCKWELL AND BRINELL HARDNESSMETHODASTM E18 · E10 · A370
Rockwell reads the permanent depth after the extra load comes off; Brinell measures the width of the dent left by a ball.
How it works

A dent you can measure.

  1. STEP 01

    Prepare the spot

    Coating and any decarburised skin are removed, and the surface is prepared at the test location.

  2. STEP 02

    Rockwell: preload

    A 10 kgf preload seats the indenter and sets the zero: a diamond cone for the C scale, a 1/16 in. ball for the B scale.

  3. STEP 03

    Rockwell: total force

    The full force is applied, 150 kgf on the C scale or 100 kgf on the B scale, pushing the indenter deeper.

  4. STEP 04

    Rockwell: read

    Back at the preload, the permanent increase in depth gives the Rockwell number directly.

  5. STEP 05

    Brinell

    A 10 mm tungsten-carbide ball is pressed in at 3000 kgf for 10 to 15 seconds, and the dent's diameter is measured.

What it can't do
  • Hardness tracks strength but does not replace a tensile test: where the two disagree on minimum strength, the tensile test decides (ASTM A962).
  • It measures the surface and just below it; for the core of a large part, a cross-section is tested.
Why it matters for fasteners

Too soft is weak. Too hard can crack.

Hardness follows strength and heat treatment, so it catches a lot that was tempered wrong. It also sets ceilings: B7 and B16 may not exceed 321 HBW (35 HRC).

Grades for sour (hydrogen sulfide) service are tempered softer and capped lower: B7M and L7M studs at 235 HBW (99 HRB), 2HM and 7M nuts at 159 to 235 HBW. One over-hard part can crack in sour service, so the specifications require every piece of these grades to be hardness tested, not a sample.

Where it applies

Grades and specifications.

ASTM A193 B7M200 to 235 HBW (93 to 99 HRB); every stud or bolt tested, on its end.
ASTM A320 L7M200 to 235 HBW (93 to 99 HRB); every stud or bolt tested.
ASTM A194 2HM159 to 235 HBW (84 to 99 HRB); every nut tested.
ASTM A194 7M159 to 235 HBW (84 to 99 HRB); every nut tested.
ASTM A193 B7321 HBW or 35 HRC maximum; sampled per lot.
ASTM A194 2H248 to 327 HBW (24 to 35 HRC) up to 1-1/2 in.; sampled per lot.
MethodASTM E18 (Rockwell) and E10 (Brinell) · limits per ASTM A193, A194 and A320 by grade
On the certificate

What the report shows.

  • The scale (HRC, HRB or HBW) and each reading.
  • Where on the part the readings were taken.
  • For grades tested 100%, that every piece was tested.
Ordering

How to ask for it.

  • Name the grade; its hardness range and how often it is tested come with it.
  • For sour service, order the M grades, such as B7M studs with 2HM nuts, rather than asking for a lower hardness on B7.
Ask for this test with a quote
Questions

Hardness testing: common questions.

Where on a bolt is hardness measured?

B7M is tested on the end of the stud or bolt (ASTM A193). Generally bolts are tested on the wrench flats, head, shank or end after any coating is removed, with a section through the bolt as the referee method (ASTM F606).

Can a hardness test replace a tensile test?

No. Hardness tracks strength, but where the two disagree on minimum strength the tensile test decides (ASTM A962).

Why test every B7M stud?

Because one over-hard stud can crack in sour service and hardness can vary from piece to piece, ASTM A193 requires every B7M stud or bolt to be tested, not a sample.

Rockwell or Brinell?

Rockwell is quick and leaves a small mark, so it suits most fasteners. Brinell's larger ball averages over a bigger area and is used on large parts; ASTM F606 uses it on bolts only over 1-1/2 in.

Need this test on your next order?

Send the specification and the test you need, and we will quote it with the parts · 832-446-3442