ISO 9001 Certified·Domestic Manufacturer — Houston, TX
Hot-shot line open832-446-3442
Innovation FastenersInnovation Fasteners
HomeEmergency / Hot-shot 24/7ContactGet a Quote
Testing · Is the chemistry right, carbon and all?

Chemical analysis (heat and product)

Step by step in 3D
Press play, or step through with the arrows under the picture. Full screen from the top corner.

A laboratory chemical analysis measures the elements in a grade's chemistry table, including carbon, boron and nitrogen, which a handheld PMI analyser cannot read. It answers two questions: was the heat made to the grade (heat analysis), and is the finished part within it (product, or check, analysis).

1 · SAMPLE1 IN. STUD, CUT ACROSSMIDWAY BETWEEN CENTREAND SURFACE (ASTM A962)2 · SPARKCNiMoCrSPECTROMETERSAMPLE, FLAT FACE DOWNSPARKELECTRODEFLAT FACE AT LEAST 0.5 IN. (13 MM)ACROSS FOR STAINLESS (ASTM E1086)LIGHT FROM EACH ELEMENT, MEASUREDAGAINST REFERENCE MATERIALS3 · BURNFURNACEINFRARED CELLCSSAMPLE IN CRUCIBLECARBON AND SULFUR: COMBUSTION,INFRARED ABSORPTIONNITROGEN AND OXYGEN: INERT-GASFUSION (ASTM E1019)HHeLiBeBCNOFNeNaMgLIGHTER THAN MAGNESIUM: NOT READ BY HANDHELD XRFSPARK EMISSION AND COMBUSTION READ C, B AND NTESTCHEMICAL ANALYSIS · HEAT AND PRODUCTMETHODASTM A751 · E415 · E1086 · E1019
The product-analysis sample comes from midway between the centre and the surface of the part. A spark on its flat face makes the elements give off light for the spectrometer to measure; carbon and sulfur are measured by combustion.
How it works

Sample, spark, burn, compare.

  1. STEP 01

    Take the sample

    The steel mill analyses each heat. For a product analysis, the sample is cut from the finished part midway between the centre and the surface, or taken from a broken test specimen (ASTM A962).

  2. STEP 02

    Spark emission

    The sample's flat face is sparked. For stainless the face must be at least 0.5 in. (13 mm) across. The light from each element is measured against reference materials of similar composition: ASTM E415 for carbon and low-alloy steel, E1086 for austenitic stainless.

  3. STEP 03

    Combustion and fusion

    Carbon and sulfur are measured by burning a sample and measuring the gases it gives off. Nitrogen and oxygen are measured by melting a sample in inert gas (ASTM E1019).

  4. STEP 04

    Nickel alloys

    Nickel alloys are analysed by ICP emission spectrometry (ASTM E2594) or X-ray fluorescence (E2465), with ASTM E1473 as the referee methods.

  5. STEP 05

    Compare with the grade

    The heat analysis must meet the grade's limits as written. A product analysis may read slightly outside them, but no further than the product-analysis tolerance the specification lists for each element.

What it can't do
  • Product-analysis tolerances apply only to a product analysis, never to the heat analysis (ASTM A962, A484).
  • It is destructive: the sample is cut from a part or a test piece, so it is made on samples from the lot. PMI is the check on every piece.
  • Chemistry does not show heat treatment: B7 and B7M share one chemistry table and differ in tempering and hardness.
Why it matters for fasteners

The certificate proves the heat. A product analysis proves the part.

Every heat is analysed at the mill and the result goes on the certificate (ASTM A193, A194, A962). The bolting specifications also list how far a product analysis may stray from each limit. For B7 it is 0.02% on carbon, so studs from a heat made to 0.38 to 0.48% carbon may read 0.36 to 0.50%. Several readings from one heat may not fall both above and below the range.

Some elements decide the grade at levels a handheld analyser cannot see. L1 bolting is a boron steel with 0.001 to 0.003% boron (ASTM A320). Low carbon is what makes a stainless steel an L grade. Duplex 2205 carries 0.14 to 0.20% nitrogen, which adds to its strength and its pitting resistance.

Tighter limits can be ordered. A962 supplementary requirement S63 caps phosphorus and sulfur at 0.025% in carbon and low-alloy steel. A320 notes that L43 bolting for −150 °F may need lower phosphorus and sulfur than is normally supplied.

Where it applies

Grades and specifications.

ASTM A193 B7Carbon 0.38 to 0.48%; a product analysis may vary 0.02%.
ASTM A320 L1Boron 0.001 to 0.003%; handheld XRF cannot read boron.
ASTM A193 B8MMolybdenum 2.00 to 3.00%; product-analysis variation 0.10%.
Duplex 2205 (S32205)Nitrogen 0.14 to 0.20%, measured by inert-gas fusion.
Nickel alloy 625When the purchaser makes a check analysis, ASTM B880 limits apply (ASTM B446).
MethodASTM A751 · E415 and E1086 (spark emission) · E1019 (carbon, sulfur, nitrogen) · E1473, E2594 and E2465 (nickel alloys) · tolerances per ASTM A193, A320, A484 and B880
On the certificate

What the report shows.

  • The heat analysis, element by element, from the mill certificate.
  • Product analysis results for the lot, when ordered.
  • The heat number the results belong to.
Ordering

How to ask for it.

  • Name the grade and specification; the heat analysis comes with the certificate.
  • Ask for a product (check) analysis if you need the finished parts analysed, and say how many per lot.
  • To tighten the chemistry, say so, for example A962 S63 (phosphorus and sulfur 0.025% max). For stainless bar, ASTM A484 lets the purchaser set tighter limits or add a limit on an element the grade does not list.
Ask for this test with a quote
Questions

Chemical analysis: common questions.

Does PMI replace a lab analysis?

No. Handheld XRF cannot read elements lighter than magnesium, which include carbon, boron and nitrogen. Spark emission and combustion analysis read them.

Why may a product analysis fall outside the grade's range?

The specifications allow a small product-analysis variation for each element, beyond the heat limits. It applies only to a product analysis, never to the heat analysis (ASTM A962).

Who makes the product analysis?

It is an optional check, made when the order or the purchaser calls for it; ASTM A962 lets the manufacturer, the purchaser or the end user make it. For nickel-alloy bar, check analysis is the purchaser's responsibility (ASTM B637).

Can a lab analysis tell 316 from 316L?

Yes. Spark emission to ASTM E1086 reads carbon from 0.005% and combustion to E1019 from 0.001%, so the low carbon of an L grade can be confirmed. Handheld XRF cannot read carbon.

Need this test on your next order?

Send the specification and the test you need, and we will quote it with the parts · 832-446-3442
Get a Quote