ISO 9001 Certified·Domestic Manufacturer — Houston, TX
Hot-shot line open832-446-3442
Innovation FastenersInnovation Fasteners
HomeEmergency / Hot-shot 24/7ContactGet a Quote
Testing · Is the alloy what the paperwork says?

Positive Material Identification (PMI)

Step by step in 3D
Press play, or step through with the arrows under the picture. Full screen from the top corner.

A handheld X-ray fluorescence (XRF) analyser reads the alloying elements of a finished part in seconds, without damaging it. It answers one question: is this part the alloy the paperwork says it is?

ANALYSER SCREEN (EXAMPLE)FeCrMnMoNiMATCH: CR-MO ALLOY STEELCARBON IS NOT READ BY XRFHANDHELD XRF ANALYSERX-RAYS IN, FLUORESCENT X-RAYS BACKTEST SPOT: COATING REMOVEDPART UNDER TESTResult goes on the test reportTESTPOSITIVE MATERIAL IDENTIFICATION (PMI)METHODASTM E1476 · HANDHELD XRF
The analyser's X-rays make each element in the metal give off X-rays of its own. Counting them gives the chemistry, which is compared with the grade.
How it works

A reading takes seconds.

  1. STEP 01

    Clean a spot

    PTFE coating, plating, paint or scale is taken off a small spot, because XRF reads only the surface it sees.

  2. STEP 02

    Take the reading

    The analyser is held against the spot. Its X-ray beam makes each element in the metal give off X-rays at an energy unique to that element.

  3. STEP 03

    Read the chemistry

    The analyser counts those X-rays and reports how much of each element is there: chromium, molybdenum, nickel, vanadium and the rest.

  4. STEP 04

    Compare with the grade

    The reading is checked against the chemistry the material specification sets for the grade.

  5. STEP 05

    Record the result

    The result goes on the test report against the heat and the parts tested.

What it can't do
  • Handheld XRF cannot read carbon or the other light elements, so it cannot tell 316L from 316H, or one plain carbon steel from another. Carbon is confirmed from the mill certificate or by spark optical-emission (OES) analysis.
  • It reads the surface: plating or coating has to come off at the test spot.
  • It sees chemistry, not heat treatment. B7M differs from B7 in its tempering and its hardness limit, which a chemical reading cannot show; a hardness test tells them apart.
Why it matters for fasteners

Bolting grades that look the same are not interchangeable.

A B8 and a B8M stud look identical, but only the B8M has the molybdenum that resists pitting. A B16 stud needs the vanadium that a B7 does not have. Nickel-alloy studs in 625 and 718 look alike but are not interchangeable.

Mix-ups happen at the mill, in a warehouse and on site, and a mill certificate cannot catch a bar that was swapped after it left the mill. PMI checks the finished part itself, so the chemistry on the certificate and the part in the box are proven to match.

ASTM A962, the common-requirements standard behind A193, A194 and A320, has a supplementary requirement for PMI of 100% of the bolting, with any part of the wrong grade rejected.

Where it applies

Grades and specifications.

Inconel 718 and 625Look-alike nickel alloys that differ in service.
Duplex 2205 and super duplexChromium, molybdenum and nickel confirmed against the grade.
ASTM A193 B8MMolybdenum checked, so a B8 cannot ship as a B8M.
ASTM A193 B16Vanadium confirmed; it is what separates B16 from B7.
Mixed-grade ordersAny order that ships more than one grade, where parts could be mixed.
MethodASTM E1476 · results reported against the grade's chemistry in ASTM A193, A194, A320 or the alloy specification
On the certificate

What the report shows.

  • The grade or alloy each tested part matched.
  • Element readings, when you ask for them.
  • The heat number, and how many parts were tested.
Ordering

How to ask for it.

  • Write PMI on the purchase order and say whether you need every piece or a sample from each lot.
  • If your plant has its own PMI procedure, send it with the order.
  • For coated parts, say so, so the test is planned before the coating goes on.
Ask for this test with a quote
Questions

Positive Material Identification: common questions.

Can a coated or plated stud be PMI tested?

Yes. The part is tested before it is coated, or a small spot is cleaned back to bare metal, because XRF reads only the surface.

Does PMI replace the mill certificate?

No. The mill certificate gives the full chemistry of the heat, including carbon. PMI proves the finished part matches it.

Can PMI tell B7 from B7M?

No. B7M differs from B7 in how it is tempered and in its hardness limit, which a chemical reading cannot see. A hardness test tells them apart.

Does the test mark the part?

No. XRF is non-destructive; only the small cleaned spot shows.

Need this test on your next order?

Send the specification and the test you need, and we will quote it with the parts · 832-446-3442
Get a Quote