ISO 9001 Certified·Domestic Manufacturer — Houston, TX
Hot-shot line open832-446-3442
Innovation FastenersInnovation Fasteners
HomeEmergency / Hot-shot 24/7ContactGet a Quote
Testing · Is the bar sound all the way through?

Ultrasonic testing (UT)

Step by step in 3D
Press play, or step through with the arrows under the picture. Full screen from the top corner.

Ultrasonic testing looks inside a part. A transducer sends sound pulses into the metal and listens for echoes: a flaw inside returns an echo before the far side does, so the whole of a bar can be checked without cutting it.

MOVED ALONG AND ROUND THE BARSCREEN (A-SCAN)INITIAL PULSEFLAWBACK WALLTIME (DEPTH) →TRANSDUCER ON COUPLANTSOUND THROUGH THE DIAMETERINTERNAL FLAWBACK WALL (FAR SIDE)PLAIN BAR,BEFORE THREADINGTESTULTRASONIC TESTING (UT) · STRAIGHT BEAMMETHODASTM A388 · E114 · A962
Straight-beam UT across a bar before it is threaded: the screen shows the start pulse, an echo from the flaw, and the echo from the far side of the bar (the back wall).
How it works

Sound in, echoes back.

  1. STEP 01

    Couplant

    A film of gel or oil on the surface lets the sound pass from the transducer into the metal.

  2. STEP 02

    Set up the instrument

    The instrument is set on the part or a reference block so a known reflector gives a known echo.

  3. STEP 03

    Scan

    The transducer is moved along and around the bar so the beam passes through the whole cross-section.

  4. STEP 04

    Read the echoes

    A flaw shows as an echo before the back wall; a big drop in the back-wall echo is a warning too.

  5. STEP 05

    Evaluate and record

    Indications are judged against the acceptance criterion on the order and recorded.

What it can't do
  • Very short or irregular parts are hard to test; it suits bar, studs and plain shanks.
  • It needs an acceptance criterion; without one there is nothing to judge an echo against.
Why it matters for fasteners

A sound surface can hide a bad middle.

Defects from steelmaking and forging, such as pipe, bursts and large inclusions, sit inside the bar where neither magnetic particle nor penetrant can see them. In a large-diameter stud carrying a heavy load, an internal flaw is a weak section no surface check will find.

ASTM A962 has a supplementary requirement for ultrasonic examination of bolting over 2 in. in cross-section, done before threading, with rejection set by the size of the echo and the loss of back reflection.

Where it applies

Grades and specifications.

Bolting over 2 in.Examined before threading when the purchaser specifies it.
Turbine boltingHigh-temperature alloy bolting in critical joints.
Heat-exchanger studsLong, highly loaded studs.
MethodASTM A388 and E114
On the certificate

What the report shows.

  • Instrument, transducer and set-up.
  • The acceptance criterion and the result.
  • Location of any recordable indications.
Ordering

How to ask for it.

  • Ask for UT and give the acceptance criterion or the specification to test to.
  • Say whether every piece or a sample is to be tested.
Ask for this test with a quote
Questions

Ultrasonic testing: common questions.

Can UT replace magnetic particle inspection?

No; they find different things. UT looks for internal flaws; magnetic particle and penetrant look at the surface, including thread roots.

Why test before threading?

The transducer needs a smooth surface to sit on. Thread crests break the contact and scatter the sound, so bar is tested while it is still plain.

Need this test on your next order?

Send the specification and the test you need, and we will quote it with the parts · 832-446-3442
Get a Quote